Compare Products

Hide

Clear All

VS

RG-S6150-48VS8CQ-X Anahtarlar - 1
RG-S6150-48VS8CQ-X Anahtarlar - 2
RG-S6150-48VS8CQ-X Anahtarlar - 3
RG-S6150-48VS8CQ-X Anahtarlar - 4
RG-S6150-48VS8CQ-X Anahtarlar - 5
RG-S6150-48VS8CQ-X Anahtarlar - 6
RG-S6150-48VS8CQ-X Anahtarlar - 7
RG-S6150-48VS8CQ-X Anahtarlar - 8
RG-S6150-48VS8CQ-X Anahtarlar - 9
RG-S6150-48VS8CQ-X Anahtarlar - 10
RG-S6150-48VS8CQ-X Anahtarlar - 1
RG-S6150-48VS8CQ-X Anahtarlar - 2
RG-S6150-48VS8CQ-X Anahtarlar - 3
RG-S6150-48VS8CQ-X Anahtarlar - 4
RG-S6150-48VS8CQ-X Anahtarlar - 5
RG-S6150-48VS8CQ-X Anahtarlar - 6
RG-S6150-48VS8CQ-X Anahtarlar - 7
RG-S6150-48VS8CQ-X Anahtarlar - 8
RG-S6150-48VS8CQ-X Anahtarlar - 9
RG-S6150-48VS8CQ-X Anahtarlar - 10
Picture

RG-S6150-48VS8CQ-X 48-Port 25GE All-Optical Layer 3 Managed Core & Aggregation Switch, 100G Uplink

Core or aggregation switch for small and medium-sized networks, supporting the smooth evolution to 25G campus networks

Models
Series
Highlight Features
  • Rich port types, 48 x 1GE/10GE/25GE SFP28 ports, and 8 x 40GE/100GE QSFP28 ports for uplink
  • VSU virtualization, flexible networking and high performance
  • Hardware redundancy, guaranteed service continuity and network connectivity
  • Layer 3 routing control, adaptive to multiple services, efficient and guaranteed data transmission
  • Network security policies and real-time monitoring, delivering enhanced network robustness
  • Paired with INC for simplified and efficient O&M
Sales Enquiry
Ana Teknik Özellikler View More
Features

Layer 3 25GE All-Optical Core & Aggregation Switch
RG-S6150-48VS8CQ-X

High-density core switch for small and medium-sized networks, or aggregation switch for large networks, with 48 x 25G service ports and eight 100G uplink ports
Flexible access capabilities, which fully cater to the requirements of high-performance networks

VSU Virtualization, Flexible Networking and High Performance

Millisecond Failover

High Scalability

Simplified Networking

The VSU connects to peripherals through an aggregate link, realizing service switching in milliseconds upon a failure.

Hardware Redundancy, Guaranteed Service Continuity
and Network Connectivity

Hot-Swappable Power Modules + Intelligent Fan Modules

Hardware-Level Boot Redundancy

Optical Port Fault Isolation

Power modules can be replaced without affecting device operation. Intelligent fan speed regulation is supported for efficient cooling,
providing dual protection for the network.

Layer 3 Routing Control, Adaptive to Multiple Services, Efficient and
Guaranteed Data Transmission

IPv4 and IPv6 Protocols

Abundant Multicast Protocols

Static and Dynamic Routing

The hardware supports dual stack for high-speed switching, catering to the requirements of campus network transition from IPv4 protocol to IPv6 protocol,
with significant improvement in address table capacity and network security.

Network Security Policies and Real-Time Monitoring, Delivering
Enhanced Network Robustness

CPP

NFPP

Large amounts of data from different sources are handled by CPP first to prevent direct attacks on the CPU, ensuring CPU stability under high usage,
and achieving significant improvement in the device's security performance.

Managed by the INC Controller to Achieve Easy and Efficient O&M Management

The switch automatically completes registration and
configuration after it accesses the all-optical network, achieving
plug and play, no commissioning and fast onboarding.
A switch can be flexibly replaced based on service needs
without reconfiguration. Service ports supports auto-sensing,
achieving automatic O&M.

Fast Onboarding

Zero Touch Replacement

Specifications

Hardware Specifications

Port Specifications

Port specifications

RG-S6150-24VS8CQ-X

RG-S6150-48VS8CQ-X

Fixed service port

24 x 1GE/10GE/25GE SFP28 ports (25GE capable with a license)

8 x 40GE/100GE QSFP28 ports (supporting 4 x 10GE/4 x 25GE)

48 x 1GE/10GE/25GE SFP28 ports (25GE capable with a license)

8 x 40GE/100GE QSFP28 ports (supporting 4 x 10GE/4 x 25GE)

Module slot

2 x power module slots

4 x fan module slots

2 x power module slots

4 x fan module slots

Power module

RG-PA550I II-F

RG-PA550I II-F

Fan module

M1EFAN II-F (pre-installed 4)

M1EFAN II-F (pre-installed 4)

Fixed management port

1 x RJ45 console port

1 x RJ45 MGMT port

1 x RJ45 console port

1 x RJ45 MGMT port

USB

1 x USB 2.0 port

1 x USB 2.0 port

 

System Specifications

System specifications

RG-S6150-24VS8CQ-X

RG-S6150-48VS8CQ-X

System switching capacity *1

2.8 Tbps

4 Tbps

CPU

Quad-core CPU, each core with the clock speed of 2.2 GHz

Quad-core CPU, each core with the clock speed of 2.2 GHz

Real-time clock (RTC)

Supported

Supported

BootROM

16 MB

16 MB

Flash memory

8 GB

8 GB

Memory

4 GB DDR4

4 GB DDR4

Switch buffer

35 MB

35 MB

Number of MAC addresses

Number of global MAC addresses: 128,000 (default)

Number of static MAC addresses: 10,000

ARP table size

96,000 (default)

ND table size

80,000 (default)

Number of IPv4 unicast routes

350,000 (default)

Number of IPv4 multicast routes

4,000

Number of IPv6 unicast routes

65,000 (default)

Number of IPv6 multicast routes

2,000

Number of ACEs

Ingress: 28,000

Egress:4,000

Number of IGMP groups

4,000

Number of MLD groups

1,000

Number of VSU members

4

 

Number of VRFs

1,024

 

*1 means the system's switching capacity.

 

Power Supply and Consumption

Power supply and consumption

RG-S6150-24VS8CQ-X

RG-S6150-48VS8CQ-X

Power supply

2 x pluggable power modules

2 x pluggable power modules

Power input

RG-PA550I II-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Rated input current: 3.5 A to 7.2 A

● Maximum input current: 7.2 A

Maximum output power

RG-PA550I II-F: 550 W

RG-PA550I II-F: 550 W

Maximum power consumption

270W

300 W

 

Dimensions and Weight

Dimensions and weight

RG-S6150-24VS8CQ-X

RG-S6150-48VS8CQ-X

Unit dimensions (W x D x H)

442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.)

Shipping dimensions (W x D x H)

600 mm x 550 mm x 175 mm (23.62 in. x 21.65 in. x 6.89 in.)

610 mm x 560 mm x 172 mm (24.02 in. x 22.05 in. x 6.77 in.)

Rack height

1 RU

1 RU

Unit weight

8.5 kg (18.74 lbs, with 4 fan modules)

8.5 kg (18.74 lbs, with 4 fan modules)

Shipping weight

9.65 kg (21.27 lbs)

9.91 kg (21.85 lbs)

 

Environment and Reliability

Environment and reliability

RG-S6150-24VS8CQ-X

RG-S6150-48VS8CQ-X

Temperature

Operating temperature: 0°C to 45°C (32°F to 113°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At an altitude between 3,000 m (9,842.52 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum temperature decreases by 1°C (1.8°F).

Humidity

Operating humidity: 10% to 90% RH (non-condensing)

Storage humidity: 5% to 95% RH (non-condensing)

Altitude

Storage altitude: –500 m to 5,000 m (–1640.42 ft. to +16,404.20 ft.)

Operating altitude: –500 m to 5,000 m (–1640.42 ft. to +16,404.20 ft.)

Mean time between failure (MTBF)

200,000 hours (about 22 years)

Fan

4 x pluggable fan modules

Heat dissipation

Fan cooling, front-to-rear airflow

Acoustic noise

Maximum value: < 73 dB

Power module redundancy

1+1 redundancy

Fan redundancy

3+1 redundancy

Power module hot swapping

Supported

USB hot swapping

Supported

Cable hot swapping

Supported

Power supply monitoring

Monitoring of the power supply model and status

Power supply failure alarming

Fan monitoring

Fan speed adjustment: 256 levels

Automatic speed adjustment

Fan failure alarming

Temperature monitoring

Temperature monitoring, over-temperature alarming

ESD

ESD contact/air discharge: 6 kV/8 kV

ESD susceptibility contact/air discharge: 8 kV/15 kV

Surge protection

MGMT Port: 4kV

RG-PA550I II-F: common mode 6 kV, differential mode 6 kV

 

Certifications and Regulatory Compliance

Certifications and regulatory compliance

RG-S6150-24VS8CQ-X

RG-S6150-48VS8CQ-X

Safety regulation

IEC 62368-1

EMC regulation

EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11

RoHS

European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863

 

Software Specifications

Feature

RG-S6150-X Series

Ethernet switching

Jumbo frame (maximum length: 9,216 bytes)

IEEE 802.1Q (supporting 4K VLANs)

Maximum number of VLANs that can be created: 4,094

Voice VLAN

Super-VLAN and private VLAN

MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment

GVRP

Basic QinQ and selective QinQ

STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)

ERPS (G.8032)

LACP (IEEE 802.3ad)

LLDP/LLDP-MED

Non blocking

IP service

Static and dynamic ARP

DHCP server, DHCP client, DHCP relay, and DHCP snooping

DNS

DHCPv6 server, DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping

Neighbor Discovery (ND) and ND snooping

GRE tunnel

IP routing

Static routing

SVI: 4k supported

RIP and RIPng

OSPFv2 and OSPFv3

GR

IS-ISv4 and IS-ISv6

BGP4 and BGP4+

Equal and Weighted Cost Multi-Path (ECMP)

Packet-based and flow-based load balancing

MCE

Stateless auto configuration

IPv4/IPv6 VRF

IPv4/IPv6 PBR

Multicast

IGMPv1/v2/v3 and IGMP proxy

IGMPv1/v2/v3 snooping

IGMP filtering and IGMP fast leave

PIM-DM, PIM-SM, and PIM-SSM

PIM-SSM for IPv4 and IPv6

MSDP for inter-domain multicast

MLDv1/v2

MLD snooping

MSDP

PIM-SMv6

Multicast source IP address check

Multicast source port check

Multicast querier

MPLS

MPLS L3VPN

6PE/6VPE interconnection with IPv4/IPv6 MPLS backbone network

MPLS MIB (RFC1273, 4265, 4382)

ACL and QoS

Standard IP ACLs (hardware ACLs based on IP addresses)

Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers)

Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type)

Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)

Time-based ACLs

ACL80 and IPv6 ACL

ACL redirection

Port traffic identification

Port traffic rate limiting

802.1p/DSCP/ToS traffic classification

Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences

Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ

Congestion avoidance: tail drop, RED, and WRED

Eight queues on each port

Rate limiting in each queue

L2/L3/L4 packet identification and classification

Security

Multi-AAA

RADIUS and TACAS+

Filtering of invalid MAC addresses

Broadcast storm suppression

BPDU guard

RADIUS authentication and authorization

Port- and MAC address-based 802.1x authentication

IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication

Web authentication

Hypertext Transfer Protocol Secure (HTTPS)

SSHv1 and SSHv2

Global IP-MAC binding

ICMPv6

IPv6 addressing and Path MTU Discovery

Port isolation and port security

IP source guard

SAVI

ARP spoofing prevention

CPP and NFPP

Various attack defense functions including NFPP, ARP anti-spoofing, DHCP/DHCPv6 attack defense, ICMP attack defense, ND attack defense, IP scanning attack defense, and customizing attack defense packet types

3-tuple binding (IP address, MAC address, and port) ARP spoofing prevention

3-tuple binding (IPv6 address, MAC address, and port)

Filtering of invalid MAC addresses

MAB authentication

Portal authentication and Portal 2.0 authentication

ARP check

DAI

ARP packet rate limiting

Gateway ARP spoofing prevention

Broadcast storm suppression

SSH

BPDU guard

Loose and strict RPF

uRPF ignoring default routes

Reliability

REUP

ERPS (G.8032)

RLDP

RLDP, Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control

Data Link Detection Protocol (DLDP)

IPv4 VRRP v2/v3 and IPv6 VRRP

BFD

Link monitoring, fault notification, and remote loopback based on 802.3ah (EFM)

GR for RIP, OSPF, BGP, and other routing protocols

Power modules in 1+1 redundancy mode

Hot swapping of power modules and fan modules

Hot swapping of fan modules

Device virtualization

VSU

NMS and maintenance

SPAN, RSPAN, and ERSPAN

sFlow

NTP an SNTP

FTP and TFTP

SNMP v1/v2/c3

RMON (1, 2, 4, 9)

Various types of RMON groups, including event groups, alarm groups, history groups, and statistics groups, as well as private alarm extension groups

RMON used to implement Ethernet statistics, historical statistics, and alarm functions

NETCONF

Flow-based mirroring, and N:1 and 1:N port mirroring

CWMP

gRPC

OpenFlow Special 1.3

Flow table analysis defined by all protocols

Transmission of specified packets to the controller

Configuring the controller's IP address and port

Notifying port status changes to the controller

CLI (Telnet/console), SSH, Syslog, SNMP over IPv6, Telnet v6, FTP/TFTP v6, DNS v6, and NTP for IPv6

Ruijie Could-based management

VXLAN

EVPN VXLAN tunnel establishment

LAN access to VXLAN

IPv4 over IPv4

Distributed gateway

IPv6 over IPv4

Using an SVI to connect to the VXLAN network

Using a routed interface to connect to the VXLAN network

Proxy ARP (replying with the actual MAC address))

ND proxy (replying with the actual MAC address)

ND reply (replying with the actual MAC address)

EVPN VXLAN

VXLAN static route

Anycast gateway

VXLAN bridging mode

VXLAN routing mode

Proxy ARP (replying with the gateway MAC address)

Configuring the UDP port number in VXLAN packets

Static VXLAN tunnel creation

Show More
Resources All Resources
Learn about Products or Solutions
Software and Configuration
Order Information

The switch, power module, and other components can be ordered as needed. Before ordering an expansion module or power module, contact the online customer service personnel for the latest support information about the module.

Switches and Power Modules

Model

Description

RG-S6150-24VS8CQ-X

24 x 1GE/10GE/25GE SFP28 ports (25GE capable with a license). 8 x 40GE/100GE QSFP28 ports (supporting 4 x 10GE/4 x 25GE). 4 x fan module slots (4 fan modules pre-installed). 2 x power module slots,at least one RG-PA550I II-F power module needs to be purchased.

RG-S6150-48VS8CQ-X

48 x 1GE/10GE/25GE SFP28 ports (25GE capable with a license). 8 x 40GE/100GE QSFP28 ports (supporting 4 x 10GE/4 x 25GE). 4 x fan module slots (4 fan modules pre-installed). 2 x power module slots,at least one RG-PA550I II-F power module needs to be purchased.

RG-PA550I II-F

550 W AC power module, supporting redundancy, 10 A power cord

RG-24VS-LIC

25GE port license for RG-S6150-24VS8CQ-X (24 x 1GE/10GE/25GE SFP28 ports)

RG-48VS-LIC

25GE port license for RG-S6150-48VS8CQ-X (48 x 1GE/10GE/25GE SFP28 ports)

Note:

  • 24 x 1GE/10GE/25GE SFP28 ports, 48 x 1GE/10GE/25GE SFP28 support 1GE SFP transceivers, 10GE SFP+ transceivers and 25GE SFP28 transceivers (25GE capable with a license).
  • 8 x 40GE/100GE QSFP28 ports support 40GE QSFP+ transceivers and 100GBASE QSFP28 transceivers.


Optical Transceivers and Cables

1GE

Model

Description

Mini-GBIC-GT

1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a

The port needs to be configured with auto-negotiation

MINI-GBIC-SX-MM850

1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF

MINI-GBIC-LX-SM1310

1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF

MINI-GBIC-LH40-SM1310

1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF

MINI-GBIC-ZX80-SM1550

1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF

GE-SFP-LX20-SM1310-BIDI

1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 20 km over SMF

GE-SFP-LX20-SM1550-BIDI

1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 20 km over SMF

GE-SFP-LX03-SM1310-BIDI-I

1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF

GE-SFP-LX03-SM1550-BIDI-I

1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF

Note: BiDi transceivers must be used in pairs. If one end uses GE-SFP-LX20-SM1310-BIDI, the other end must use GE-SFP-LX20-SM1550-BIDI. 


10GE

Model

Description

XG-SFP-SR-MM850

10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF

XG-SFP-LR-SM1310

10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF

XG-SFP-ER-SM1550

10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF

XG-SFP-ZR-SM1550

10GBASE-ZR, SFP+ transceiver, 1550nm, Duplex LC, 80 km over SMF

XG-SFP-LR10-SM1270-BIDI-I

10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF

XG-SFP-LR10-SM1330-BIDI-I

10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF

XG-SFP-AOC1M

10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers

XG-SFP-AOC3M

10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers

XG-SFP-AOC5M

10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers

 

25GE

Model

Description

VG-SFP-SR-MM850

25GBASE-SR, SFP28 transceiver, 850 nm, Duplex LC, 100 m over OM4 MMF, 70 m over OM3 MMF

VG-SFP-AOC5M

25GBASE, SFP28 active optical cable (AOC), 5 m, including one cable and two optical transceivers

 

40GE

Model

Description

40G-QSFP-LSR-MM850

40GBASE-LSR, QSFP+ transceiver, 850 nm, MPO 1 x 12, 400 m over OM4 MMF, 300 m over OM3 MMF

40G-QSFP-LR4-SM1310

40GBASE-LR4, QSFP+ transceiver, 1310 nm, Duplex LC, 10 km over SMF

40G-QSFP-iLR4-SM1310

40GBASE-iLR4, QSFP+ transceiver, 1310 nm, Duplex LC, 2 km over SMF

40G-AOC-5M

40GBASE, QSFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers

 

100GE

Model

Description

100G-QSFP-SR-MM850

100GBASE-SR, QSFP28 transceiver, 850 nm, MPO 1 x 12, 100 m over OM4 MMF, 70 m over OM3 MMF

100G-QSFP-LR4-SM1310

100GBASE-LR4, QSFP28 transceiver, 1310 nm, Duplex LC, 10 km over SMF

100G-AOC-10M

100GBASE, QSFP28 active optical cable (AOC), 10 m, including one cable and two optical transceivers

Show More
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Bize Ulaşın

Bize Ulaşın

How can we help you?

Bize Ulaşın

Get an Order help

Bize Ulaşın

Get a tech support