Compare Products

Hide

Clear All

VS

RG-S6580-48CQ8QC Switches - 1
RG-S6580-48CQ8QC Switches - 2
RG-S6580-48CQ8QC Switches - 3
RG-S6580-48CQ8QC Switches - 4
RG-S6580-48CQ8QC Switches - 5
RG-S6580-48CQ8QC Switches - 6
RG-S6580-48CQ8QC Switches - 1
RG-S6580-48CQ8QC Switches - 2
RG-S6580-48CQ8QC Switches - 3
RG-S6580-48CQ8QC Switches - 4
RG-S6580-48CQ8QC Switches - 5
RG-S6580-48CQ8QC Switches - 6
Picture

RG-S6580-48CQ8QC Data Center 100G High-Density Fixed Access Switch with 400GE Uplink(Backward Compatibility with 100GE)

High-density 400GE/100GE ports, supporting high-bandwidth and large-capacity server access

Modelos
Serie
Características destacadas
  • Various ports, and 48 x 100GE DSFP and 8 x 400GE QSPF-DD ports, supporting flexible networking
  • Hardware-level redundancy, ensuring nonstop services
  • Lossless Ethernet, ensuring zero packet loss in RDMA E2E communication
  • Telemetry network monitoring and automatic O&M, making management simple and efficient
Sales Enquiry
Key Specification View More
Features

Data Center 100GE Access Switch RG-S6580-48CQ8QC

The RG-S6580-48CQ8QC is a high-density access switch and provides various ports within the space of 1 RU. With improved data forwarding capabilities, it can be flexibly deployed and supports access of 100G servers. It can evolve to 100GE/400GE data centers.

Hardware-Level Redundancy, Ensuring Nonstop Services

Hot-Swappable Redundant Power Modules

Hot-Swappable Redundant Fan Modules

1+1 power modules, hot swapping, and service failover within seconds, ensuing service continuity

Lossless Ethernet, Ensuring Zero Packet Loss in RDMA E2E Communication

With RDMA enabled, communication data on the RG-S6580-48CQ8QC does not need to be handled by the CPU. This reduces the burden of the CPU and effectively resolves the latency problem. Using PFC and ECN, the RG-S6580-48CQ8QC intelligently exchanges data to prevent packet loss and ensures lossless data transmission.

Telemetry Network Monitoring and Automatic O&M, Making Management Simple and Efficient

RG-S6580-48CQ8QC enabled with Telemetry uses the push mode to proactively collect and push information and provides sub-second-level network monitoring in real time, making network management more efficient and accurate.

Especificaciones

Hardware Specifications

Item

RG-S6580-48CQ8QC

RG-S6580-24DC8QC

Dimensions (W x D x H)

442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.)

442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.)

Rack height

1 RU

1 RU

Unit weight

11.5 kg (25.35 lbs., a chassis with two power modules and six fan modules)

11 kg (24.25 lbs., a chassis with two power modules and six fan modules)

Switching capacity

16.0 Tbps

16.0 Tbps

Packet forwarding rate

5350 Mpps

5350 Mpps

Service port

48 x 100G DSFP ports

8 x 100G/400G QSFP-DD ports

24 x 40G/100G/200G QSFP56 ports

8 x 100G/400G QSFP-DD ports

Management port

1 x RJ45 console port

1 x RJ45 MGMT port

1 x RJ45 console port

1 x RJ45 MGMT port

USB port

1 x USB 2.0 port (Type A connector)

1 x USB 2.0 port (Type A connector)

Module slot

2 x power module slots

6 x fan module slots

2 x power module slots

6 x fan module slots

Power consumption

Maximum power consumption: 742 W

Typical power consumption: 633 W

Static power consumption: 178 W

Maximum power consumption: 850 W

Typical power consumption: 700 W

Static power consumption: 300 W

Power input

RG-PA1200I-F (AC input)

Rated input voltage:

100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz

Maximum input voltage:

90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current:

13.8 A(100 V AC to 127 V AC)

8.5 A (200 V AC to 240 V AC)

Power port type: C14

 

RG-PA1200I-F (HVDC input):

Rated input voltage: 240 V DC

Maximum input voltage: 180 V DC to 300 V DC

Rated current: 6.5 A

Power port type: C14

RG-PA1200I-F (AC input)

Rated input voltage:

100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz

Maximum input voltage:

90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current:

13.8 A(100 V AC to 127 V AC)

8.5 A (200 V AC to 240 V AC)

Power port type: C14

 

RG-PA1200I-F (HVDC input):

Rated input voltage: 240 V DC

Maximum input voltage: 180 V DC to 300 V DC

Rated current: 6.5 A

Power port type: C14

Temperature

Operating temperature: 0°C to 40°C (32°F to 104°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Operating temperature: 0°C to 40°C (32°F to 104°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Humidity

Operating humidity: 10% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Operating humidity: 10% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Altitude

Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Cooling

Air cooling, front-to-rear airflow (port-side intake)

Air cooling, front-to-rear airflow (port-side intake)


Software Specifications

Item

RG-S6580-48CQ8QC

RG-S6580-24DC8QC

Layer 2 Protocols

IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB)

Layer 3 Protocols (IPv4)

BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP

IPv6 Basic Protocols

Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS

IPv6 Features

Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+

Data Center Features

PFC, ECN, and other data center features

RDMA

VXLAN bridge

VXLAN gateway

IPv6 VXLAN over IPv4

IPv4 VXLAN over IPv4

ECN over VXLAN

PFC over VXLAN

Visualization

gRPC

sFlow sampling

IPFIX

QoS

Mapping of IEEE 802.1p, DSCP, and ToS priorities
ACL-based traffic classification
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding

HA Design

GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules

Security Features

Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management

Management Mode

SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm

Other Protocols

DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog

Show More
Resources All Resources
Learn about Products or Solutions
Installation
Información del pedido

Chassis, Fan Module

Product Model

Description

RG-S6580-48CQ8QC

48 × 100GE DSFP ports + 8 × 400GE QSFP-DD ports

Two power slots and six fan slots

The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules.

RG-S6580-24DC8QC

24 × 200GE QSFP56 ports + 8 × 400GE QSFP-DD ports

Two power slots and six fan slots

The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules.

 

Power Supply Module

Product Model

Description

RG-PA1200I-F

1200 W AC module (AC/240 V HVDC)

 

Fan Module

Product Model

Description

M1HFAN II-F

Fan module (front-to-rear ventilation)

 

100GE Optical Transceivers

Model

Description

100G-AOC-5M

100G AOC, QSFP28 form factor, 5 m (16.40 ft.)

100G-AOC-10M

100G AOC, QSFP28 form factor, 10 m (32.81 ft.)

100G-QSFP-SR-MM850

100G SR optical transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over multimode fiber (MMF)

100G-QSFP-iLR4-SM1310

100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

100G-QSFP-LR4-SM1310

100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

100G-QSFP-ER4-SM1310

100GE ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF

 

400GE Optical Transceivers

Model

Description

400G-QDD-SR8-MM850

400G optical transceiver, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF

400G-QDD-DR4-SM1310

400G optical transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF

400G-QDD-FR4-SM1310

400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

*400G-QDD-ZR-SM1550

400G ZR optical transceiver, QSFP-DD, Duplex LC, 1550 nm, 80 km (262,467.19 ft.) over SMF

Show More
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Contáctenos

Contáctenos

How can we help you?

Contáctenos

Get an Order help

Contáctenos

Get a tech support

Technical Support
Technical Support
Get in Touch
Get in Touch