RG-S6980-64QC – 64-Port 400GE Data Center Core Switch, 4 RU

High-density 400GE Fixed Switch with 400GE ZR/ZR+ Optical Modules, Supporting Long-Distance Interconnection 

Models
Series
Highlight Features
  • High-density 400GE switch with 64 x 400GE QSFP-DD ports in the 4-RU space

  • Hardware-level redundancy, ensuring service continuity

  • 400GE QSFP-DD ports, interconnection at the distance of up to 120 km, and smooth and rapid data communication

  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication

  • Telemetry-based network monitoring and automated O&M, making management simple and efficient

Sales Enquiry
Key Specification View More
Features
 

Data Center 400GE Core Switch RG-S6980-64QC

High-speed and high-density core switch in a data center with 64 x 400GE QSFP-DD ports in the 4 RU space, delivering scalable,
high-performance and high-bandwidth services and coping with interconnection on a large data center network

Ports

Dimensions

IPv4/IPv6 Host Routing Entries
1000K/640K

Buffer
113.66MB

Hardware-level Redundancy, Ensuring Service Continuity

Hot-Swappable Redundant Power Modules

Hot-Swappable Redundant Fan Modules

Power modules in 2+2 redundancy mode, failover in seconds, and power module replacement without network interruption, providing double protection for links

Communication at the Maximum Distance of 120 km and Easy DCI

400GE ZR/ZR+ optical modules are used for interconnection reducing intermediate transmission devices and helping a cloud or hyper-scale
data center network to adapt to growing high-bandwidth services.

Lossless Ethernet with RDMA E2E Communication
and Zero Packet Loss

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden
and effectively solves the network latency problem.
PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M,
Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy.
The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time,
making network management more efficient and accurate.

Specifications

Hardware Specifications

Item

RG-S6980-64QC

Dimensions (W × D × H)

442 mm x 760 mm x 175 mm (17.40 in. x 29.92 in. x 6.89 in.)

Rack height

4 RU

Unit weight

32.8 kg (72.31 lbs., empty chassis)

42 kg (92.59 lbs., a chassis with four power modules and eight fan modules)

Switching capacity

51.2 Tbps

Packet forwarding rate

10300 Mpps

Service port

64 x 100GE/200GE/400GE QSFP-DD ports

Management port

1 x RJ45 console port

1 x RJ45 MGMT port

USB port

1 x USB 2.0 port (Type A connector)

Power consumption

4 x power module slots

8 x fan module slots

Power consumption

Maximum power consumption: 2400 W

Typical power consumption: 1760 W

Static power consumption: 500 W

Power input

RG-PA1200I-F (AC input)

Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz

Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current: 13.8 A (100 V AC to 127 V AC)

8.5 A (200 V AC to 240 V AC)

Power port type: C14

 

RG-PA1200I-F (HVDC input):

Rated input voltage: 240 V DC

Maximum input voltage: 180 V DC to 300 V DC

Rated current: 6.5 A

Power port type: C14

Temperature

Operating temperature: 0°C to 40°C (32°F to 104°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 2000 m (6561.68 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Humidity

Operating humidity: 10% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Altitude

Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Cooling

Air cooling, front-to-rear airflow (port-side intake)

 

Software Specifications

Item

RG-S6980-64QC

Layer 2 Protocols

IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol)), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB)

Layer 3 Protocols (IPv4)

BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP

IPv6 Basic Protocols

Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS

IPv6 Features

Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+

Data Center Features

PFC, ECN, and other data center features

RDMA

VXLAN, BGP-EVPN

PFC deadlock prevention

RDLB, GDLB

Visualization

gRPC

sFLOW sampling

QoS

Mapping of IEEE 802.1p, DSCP, and ToS priorities
ACL-based traffic classification
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding

HA Design

GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules

Security Features

Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management

Management Mode

SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm

Other Protocols

DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog

Show More
Resources All Resources
Learn about Products or Solutions
Installation
Software and Configuration
Order Information

Chassis, Fan, and Power Modules

Product Model

Description

RG-S6980-64QC

Fixed 64 × 400GE ports, four power supply module slots, and eight fan slots

RG-PA1200I-F

Power supply module, supporting 2+2 redundancy, hot swapping, and front-to-rear ventilation design

M2EFAN II-F

Fan module, supporting 7+1 redundancy, hot swapping, and front-to-rear ventilation design

 

100G Optical Transceivers

Model

Description

100G-QSFP-iLR4-SM1310

100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over single-mode fiber (SMF)

100G-QSFP-LR4-SM1310

100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

100G-QSFP-SR-MM850

100G SR optical transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over multimode fiber (MMF)

100G-QSFP-ER4-SM1310

100GE ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF

100G-AOC-5M

100G AOC, QSFP28 form factor, 5 m (16.40 ft.)

100G-AOC-10M

100G AOC, QSFP28 form factor, 10 m (32.81 ft.)

 

400G Optical Transceivers

Model

Description

400G-QDD-SR8-MM850

400G SR8 optical transceiver, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF

400G-QDD-FR4-SM1310

400G FR4 optical transceiver, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

400G-QDD-DR4-SM1310

400G DR4 optical transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF

Show More
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Dane kontaktowe

Dane kontaktowe

How can we help you?

Dane kontaktowe

Get an Order help

Dane kontaktowe

Get a tech support

Technical Support
Technical Support
Get in Touch
Get in Touch