Compare Products

Hide

Clear All

VS

RG-N18010-XH Przełączniki - 1
RG-N18010-XH Przełączniki - 2
RG-N18010-XH Przełączniki - 3
RG-N18010-XH Przełączniki - 4
RG-N18010-XH Przełączniki - 5
RG-N18010-XH Przełączniki - 6
RG-N18010-XH Przełączniki - 7
RG-N18010-XH Przełączniki - 8
RG-N18010-XH Przełączniki - 9
RG-N18010-XH Przełączniki - 10
RG-N18010-XH Przełączniki - 1
RG-N18010-XH Przełączniki - 2
RG-N18010-XH Przełączniki - 3
RG-N18010-XH Przełączniki - 4
RG-N18010-XH Przełączniki - 5
RG-N18010-XH Przełączniki - 6
RG-N18010-XH Przełączniki - 7
RG-N18010-XH Przełączniki - 8
RG-N18010-XH Przełączniki - 9
RG-N18010-XH Przełączniki - 10
Picture

RG-N18010-XH – Next Generation Data Center Network High-Density Centralized Modular Core Switch with 100GE/400GE Line Cards and Eight Service Slots

Adaptation to 400GE ZR/ZR+ optical modules, up to 288 x 400GE and 1152 x 100GE line-rate ports, and smooth evolution to 800GE

Models
Series
Highlight Features
  • 100GE and 400GE line cards, and up to 288 x 400GE and 1152 x 100GE line-rate ports

  • Communication at the maximum distance of 120 km and easy DCI

  • Hardware-level redundancy, ensuring nonstop services and data center network stability

  • MACsec data encryption and transmission, effectively protecting service data security

  • Innovative technology design and efficient heat dissipation, with more than 50,000 kWh saved per device each year

  • Telemetry-based network monitoring and automated O&M, making management simple and efficient...

Sales Enquiry
Key Specification View More
Features

Data Center 400GE Modular
Core Switch
RG-N18010-XH

The RG-N18010-XH provides 10 module
slots, including eight service slots, which can
be used with 100GE and 400GE line cards. It
supports 800GE line cards in the future,
easily coping with future bandwidth
expansion needs.
With various port types, the RG-N18010-XH
supports up to 288 x 400GE and 1152 x
100GE line-rate ports, and allows smooth
evolution to 800GE, satisfying requirements
in diversified scenarios of data center
networks.

Innovative Architecture Design,
Achieving Highly Efficient Data Transmission

Zero Midplane

Clos Architecture

Service line cards are directly connected to SFUs, without the use of the midplane. Data can directly reach the SFU, with a
short distance. This significantly reduces the transmission loss and achieves efficient data transmission.

Communication at the Maximum Distance of 120 KM and Easy DCI

400GE ZR/ZR+ optical modules are used for interconnection, reducing Optical Transport Units (OTUs) and helping a cloud or hyper-scale
data center network to adapt to growing high-bandwidth services

Hardware-level Redundancy,
Ensuring Nonstop Services and Data
Center Network Stability

SFUs in N+1 Redundancy Mode
SFUs use N+1 redundancy and work in load balancing
mode, ensuring nonstop services.
Power Modules in M+N Redundancy Mode
Ten hot-swappable power modules are available. When a
fault occurs, services are switched within seconds. Services
are not interrupted when a power module is replaced. The
switch provides different protection measures for links.
Fan Trays in 2+1 Redundancy Mode
Three hot-swappable fan trays are available. The speed of
fan modules can be intelligently adjusted, ensuring highly
efficient heat dissipation.
Supervisor Engin es in 1+1 Redundancy Mode
The 1+1 hot standby design ensure continuous operation of
the switch.

Innovative Technology Design and Highly Efficient Heat Dissipation

MACsec Data Encryption and Transmission,
Effectively Protecting Service Data Security

MACsec provides hardware-level data encryption. With MACsec and 802.1X configured, the switch can strictly identify and verify transmitted data.
With MACsec, the switch achieves interface-based secure line-rate transmission, effectively preventing data from being intercepted and obtained maliciously
and ensuring service data security.

Telemetry-based Network Monitoring and Automated O&M,
Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy.
The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time,
making network management more efficient and accurate.

Specifications

Hardware Specifications

Item

RG-N18018-XH

RG-N18010-XH

Dimensions (W x D x H)

442 mm x 1052 mm x 1345 mm (17.40 in. x 41.42 in. x 52.95 in.), without the cable management bracket;

442 mm x 1091 mm x 1345 mm (17.40 in. x 42.95 in. x 52.95 in.), with the cable management bracket.

442 mm x 896 mm x 708 mm (17.40 in. X 35.28 in. X 27.87 in.), without the cable management bracket;

442 mm x 935 mm x 708 mm (17.40 in. x 36.81 in. X 27.87 in.), with the cable management bracket.

Rack height

31 RU

16 RU

Unit weight

205 kg (451.95 lbs.), with M18018XH-FAN fan modules;

186 kg (410.06 lbs.), with M18018XH-FAN III fan modules.

96.4 kg (212.53 lbs.) (Chassis that supports the M18000XH-CM supervisor module)

99 kg (218.26 lbs.) (Chassis that supports the M18000XH-CM II supervisor module)

Switching capacity

1,290 Tbps/3,870 Tbps

645 Tbps/1,935 Tbps

Packet forwarding rate

691,200 Mpps

345,600 Mpps

Module slot

2 x supervisor module slots

16 x line card slots

8 x switch fabric module slots

20 x power module slots

3 x fan module slots

2 x supervisor module slots

8 x line card slots

8 x switch fabric module slots

10 x power module slots

3 x fan module slots

Power consumption

Maximum power consumption (with the M18018XH-FAN fan module): 38,900 W

Maximum power consumption (with the M18018XH-FAN III fan module): 18,000 W

Maximum power consumption (with the M18010XH-FAN fan module): 187,600 W

Maximum power consumption (with the M18010XH-FAN III fan module): 9000 W

Power input

RG-PAH3000I-F (AC input):

Rated input voltage: 100 V AC to 130 V AC, 200 V AC to 240 V AC, 50 Hz/60 Hz

Maximum input voltage: 90 V AC to 290 V AC, 45 Hz to 65 Hz

Rated input current: 16 A

Power port type: C20

 

RG-PAH3000I-F (HVDC input):

Rated input voltage: 240 V DC to 380 V DC

Maximum input voltage: 188 V DC to 400 V DC

Rated input current: 14 A

Power port type: C20

Note: When the switch is equipped with the high-voltage DC power supply, a PDU that supports high-voltage DC power supply must be used. To ensure safety, connect the external power supply to the power cord first and then to the PDU. The switch can only connect to a specific power system (UPS) but not to the DC power grid. The DC voltage tolerance range is from 188 V DC to 400 V DC.

 

PD2200II-F (DC input):

Rated input voltage: –48 V DC to –60 V DC

Maximum input voltage: –38 V DC to –72 V DC

Rated input current: 50 A

Power port type: Rectangular non-metallic locking plug

RG-PAH3000I-F (AC input):

Rated input voltage: 100 V to 130 VAC, 200 V AC to 240 V AC, 50 Hz/60 Hz

Maximum input voltage: 90 V AC to 290 V AC, 45 Hz to 65 Hz

Rated input current: 16 A

Power port type: C20

 

RG-PAH3000I-F (HVDC input):

Rated input voltage: 240 V DC to 380 V DC

Maximum input voltage: 188 V DC to 400 V DC

Rated input current: 14 A

Power port type: C20

Note: When the switch is equipped with the high-voltage DC power supply, a PDU that supports high-voltage DC power supply must be used. To ensure safety, connect the external power supply to the power cord first and then to the PDU. The switch can only connect to a specific power system (UPS) but not to the DC power grid. The DC voltage tolerance range is from 188 V DC to 400 V DC.

 

PD2200II-F (DC input):

Rated input voltage: –48 V DC to –60 V DC

Maximum input voltage: –38 V DC to –72 V DC

Rated input current: 50 A

Power port type: Rectangular non-metallic locking plug

Temperature

Operating temperature: 0°C to 40°C (32°F to 104°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Humidity

Operating humidity: 10% RH to 90% RH (non-condensing)

Altitude

Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Cooling

Air cooling, front-to-rear airflow (port-side air intake)

 

Software Specifications

Item

RG-N18018-XH

RG-N18010-XH

Traffic analysis

sFlow

IPFIX

Layer 2 features

Jumbo frame

IEEE 802.3ad (static link aggregation, LACP, cross-module link aggregation, and M-LAG)

IEEE 802.1Q

STP, RSTP, and MSTP

GVRP

QinQ

LLDP

Static MAC addresses, address filtering, and limit on the number of MAC addresses

IPv4 features

Static routing, BGP4, OSPF, IS-IS, and RIP

VRRP

ECMP

Policy-based routing

IP fragmentation and reassembly

Manual tunnel and GRE tunnel

IPv6 features

Static routing, BGP4+, OSPFv3, IS-ISv6, and RIPng

VRRPv3

ECMP

Policy-based routing

Path MTU discovery

IP fragmentation and reassembly

Manual tunnel and GRE tunnel

Pingv6, Traceroutev6, Telnetv6, FTPv6, TFTPv6, DNSv6, and ICMPv6

Multicast

IGMP v1/v2/v3

IGMP Snooping v1/v2

IGMP proxy

PIM-DM, PIM-SM, PIM-SSM, and PIM-SM v6

MLDv1, MLDv2

Static multi cast route

Fast leave

MPLS

MPLS L3VPN

MPLS LDP

SR MPLS (Segment Routing)

SR-TE

ACL

Standard, extended (Layer 2 to layer 4), and expert ACL

Global ACL

Ingress and egress ACL

IPv6 ACL

QoS

IEEE 802.1p, ToS, and DSCP priority mapping

Priority marking and remarking

SP(PQ), DRR, SP(PQ)+DRR, WFQ, SP(PQ)+WFQ, and other queue scheduling mechanisms

Congestion avoidance mechanisms such as RED and WRED

ACL

Egress/ingress port-based rate limit and CAR

#MPLS QoS

Data center features

#SRv6

VXLAN bridge

VXLAN gateway

BGP-EVPN VXLAN

VXLAN mapping

VXLAN over IPv4

VXLAN over IPv6

M-LAG

RDMA

SDN

OpenFlow 1.3

Reliability

Independent switch fabric modules and independent supervisor modules to implement thorough separation of the forwarding plane from the control plane

1+1 redundancy for supervisor modules

N+M redundancy for switch fabric modules

N+M redundancy for power modules and fan modules

Midplane-free design to avoid single point of failures

Hot swapping of components

Hot patching for online patch upgrade

BPDU Guard/Loop Guard/Root guard

NSR

DLDP

FRR

GR for OSPF/IS-IS/BGP

BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/Static routing

Virtualization

Virtual switching unit (VSU)

Security

#MACSec

Network foundation protection protocol (NFPP) and CPU Protection Policy (CPP)

DDoS attack defense, ARP attack defense, and ICMP attack defense

DAI, port security, IP source guard, and port protection

uRPF

RADIUS and TACACS authentication, password security, hierarchical user management, and password protection

Source IP address restriction

Configuring the device not to send unknown multicast packets to the CPU

Suppression of unknown unicast, broadcast, and multicast packets

SSHv2, providing secure encrypted channels for user login

MAC address flapping protection policy

Clear text and MD5 authentication for BGP4, BGP4+, OSPF, OSPFv3, IS-IS, IS-ISv6, and RIPv2 packets

Management

Console/AUX Modem/Telnet/SSHv2 CLI configuration

FTP, TFTP, Xmodem, and SFTP

SNMP v1/v2c/v3

Netconf

RMON

NTP clock

Fault alarm and auto-recovery

System operation log

Traffic analysis

Zero-Touch provisioning (ZTP)

Reliable network service (RNS), which probes specific services provided by the peer device to monitor the service availability

Telemetry

Buffer status monitoring and traffic microburst identification

Supported VXLAN OAM: VXLAN ping VXLAN tracert

Port mirroring, traffic mirroring, and ERSPAN

Physical ports on all line cards support routing mode and can be configured with IP addresses independently

Fan and power module monitoring

# indicates that the feature is supported only by CE line cards.

Show More
Resources All Resources
Learn about Products or Solutions
Installation
Order Information

Chassis and Supervisor Modules

Model

Description

RG-N18018-XH

RG- N18018-XH switch, fully equipped with fan modules, without power modules

RG-N18010-XH

RG-N18010-XH chassis, fully equipped with fan modules, without power modules

M18000XH-CM

M18000XH-CM supervisor module, used with Type E switch fabric modules and CE line cards

M18000XH-CM II

M18000XH-CM II supervisor module, used with Type D switch fabric modules and DB line cards

 

Power Module

Model

Description

RG-PAH3000I-F

3000 W AC power module (supporting AC and 240 V to 380 V HVDC)

PD2200II-F

2200 W DC power module (supporting 54 V DC), applicable to RG-N18018-XH and RG-N18010-XH

 

Switch Fabric Module

Model

Description

M18018XH-FE-E IV

Type E series switch fabric module of RG-N18018-XH, used with CE line cards

M18018XH-FE-D II

Type D switch fabric module of RG-N18018-XH, used with DB line cards

M18010XH-FE-E II

Type E series switch fabric module of RG-N18010-XH, used with CE line cards

M18010XH-FE-D II

Type D switch fabric module of RG-N18010-XH, used with DB line cards

M18006XH-FE-D I

Type D switch fabric module of RG-N18006-XH, used with DB line cards

 

Line Cards and Function Modules

Model

Description

M18000XH-36QC-CES

36-port 400G (QSFP-DD) Ethernet optical interface card, CE line card, used together with Type E switch fabric modules

M18000XH-48CQ-CES

48-port 100G QSFP28 Ethernet optical interface card, CE line card, used with Type E series switch fabric modules

M18000XH-36CQ-DB

36-port 100G QSFP28 Ethernet optical interface card, DB line card, used with Type D switch fabric modules

M18000XH-18CQ-DB

18-port 100G QSFP28 Ethernet optical interface card, DB line card, used with Type D switch fabric modules

M18000XH-36QXS-DB

36-port 40G QSFP+ Ethernet optical interface card, DB line card, used with Type D switch fabric modules

M18000XH-48XS-DB

48-port 10G SFP+ Ethernet optical interface card, DB line card, used with Type D switch fabric modules


25G Optical Transceivers

Model

Description

VG-SFP-AOC5M

25G active optical cable (AOC), SFP28 form factor, 5 m (16.40 ft.)

VG-SFP-SR-SM850

25G SR optical transceiver, SFP28 form factor, LC interface, 850 nm, 100 m (328.08 ft.) over multimode fiber (MMF)

VG-SFP-LR-SM1310

25G LR4 optical transceiver, SFP28 form factor, LC interface, 1310 nm, 10 km (32,808.40 ft.) over single-mode fiber (SMF)


40G Optical Transceivers

Model

Description

40G-QSFP-LX4-SM1310

40G LX4 optical transceiver, QSFP+ form factor, Duplex LC, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF

40G-QSFP-LR4-SM1310

40G LR4 optical transceiver, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF

40G-QSFP-iLR4-SM1310

40G iLR4 optical transceiver, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF

40G-QSFP-LSR-MM850

40G SR optical transceiver, QSFP+ form factor, MPO interface, 400 m (1,312.34 ft.) over MMF

40G-QSFP-SR-MM850

40G SR optical transceiver, QSFP+ form factor, MPO interface, 150 m (492.13 ft.) over MMF

40G-AOC-30M

40G QSFP+ AOC, 30 m (98.43 ft.)

40G-AOC-5M

40G QSFP+ AOC, 5 m (16.40 ft.)

 

100G Optical Transceivers

Model

Description

100G-QSFP-LR4-SM1310

100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

100G-QSFP-iLR4-SM1310

100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

100G-QSFP-ER4-SM1310

100G ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF

100G-QSFP-SR-MM850

100GSR optical transceiver, QSFP28 form factor, MPO interface, 850 nm, 100 m (328.08 ft.) over MMF

100G-AOC-5M

100G AOC, QSFP28 form factor, 5 m (16.40 ft.)

100G-AOC-10M

100G AOC, QSFP28 form factor, 10 m (32.81 ft.)

 

400G Optical Transceivers

Model

Description

400G-QDD-DR4-SM1310

400G optical transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF

400G-QDD-FR4-SM1310

400G FR4 optical transceiver, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

400G-QDD-ZR-SM1550

400G ZR optical transceiver, QSFP-DD form factor, Duplex LC, 1550 nm, 80 km (262,467.19 ft.) over SMF

400G-QDD-SR8-MM850

400G optical transceiver, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF

Show More
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Dane kontaktowe

Dane kontaktowe

How can we help you?

Dane kontaktowe

Get an Order help

Dane kontaktowe

Get a tech support

Technical Support
Technical Support
Get in Touch
Get in Touch