High-density 400GE/100GE ports, supporting high-bandwidth and large-capacity server access
Hardware Specifications
Item |
RG-S6580-48CQ8QC |
RG-S6580-24DC8QC |
Dimensions (W x D x H) |
442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.) |
442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.) |
Rack height |
1 RU |
1 RU |
Unit weight |
11.5 kg (25.35 lbs., a chassis with two power modules and six fan modules) |
11 kg (24.25 lbs., a chassis with two power modules and six fan modules) |
Switching capacity |
16.0 Tbps |
16.0 Tbps |
Packet forwarding rate |
5350 Mpps |
5350 Mpps |
Service port |
48 x 100G DSFP ports 8 x 100G/400G QSFP-DD ports |
24 x 40G/100G/200G QSFP56 ports 8 x 100G/400G QSFP-DD ports |
Management port |
1 x RJ45 console port 1 x RJ45 MGMT port |
1 x RJ45 console port 1 x RJ45 MGMT port |
USB port |
1 x USB 2.0 port (Type A connector) |
1 x USB 2.0 port (Type A connector) |
Module slot |
2 x power module slots 6 x fan module slots |
2 x power module slots 6 x fan module slots |
Power consumption |
Maximum power consumption: 742 W Typical power consumption: 633 W Static power consumption: 178 W |
Maximum power consumption: 850 W Typical power consumption: 700 W Static power consumption: 300 W |
Power input |
RG-PA1200I-F (AC input) Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 13.8 A(100 V AC to 127 V AC) 8.5 A (200 V AC to 240 V AC) Power port type: C14
RG-PA1200I-F (HVDC input): Rated input voltage: 240 V DC Maximum input voltage: 180 V DC to 300 V DC Rated current: 6.5 A Power port type: C14 |
RG-PA1200I-F (AC input) Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 13.8 A(100 V AC to 127 V AC) 8.5 A (200 V AC to 240 V AC) Power port type: C14
RG-PA1200I-F (HVDC input): Rated input voltage: 240 V DC Maximum input voltage: 180 V DC to 300 V DC Rated current: 6.5 A Power port type: C14 |
Temperature |
Operating temperature: 0°C to 40°C (32°F to 104°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
Operating temperature: 0°C to 40°C (32°F to 104°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
Humidity |
Operating humidity: 10% RH to 90% RH (non-condensing) Storage humidity: 5% RH to 95% RH (non-condensing) |
Operating humidity: 10% RH to 90% RH (non-condensing) Storage humidity: 5% RH to 95% RH (non-condensing) |
Altitude |
Operating altitude: ≤ 5,000 m (16,404.20 ft.) Storage altitude: ≤ 5000 m (16,404.20 ft.) |
Operating altitude: ≤ 5,000 m (16,404.20 ft.) Storage altitude: ≤ 5000 m (16,404.20 ft.) |
Cooling |
Air cooling, front-to-rear airflow (port-side intake) |
Air cooling, front-to-rear airflow (port-side intake) |
Software Specifications
Item |
RG-S6580-48CQ8QC |
RG-S6580-24DC8QC |
Layer 2 Protocols |
IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) |
|
Layer 3 Protocols (IPv4) |
BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP |
|
IPv6 Basic Protocols |
Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS |
|
IPv6 Features |
Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+ |
|
Data Center Features |
PFC, ECN, and other data center features RDMA VXLAN bridge VXLAN gateway IPv6 VXLAN over IPv4 IPv4 VXLAN over IPv4 ECN over VXLAN PFC over VXLAN |
|
Visualization |
gRPC sFlow sampling IPFIX |
|
QoS |
Mapping of IEEE 802.1p, DSCP, and ToS priorities |
|
HA Design |
GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules |
|
Security Features |
Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management |
|
Management Mode |
SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm |
|
Other Protocols |
DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog |
Chassis, Fan Module
Product Model |
Description |
RG-S6580-48CQ8QC |
48 × 100GE DSFP ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. |
RG-S6580-24DC8QC |
24 × 200GE QSFP56 ports + 8 × 400GE QSFP-DD ports Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. |
Power Supply Module
Product Model |
Description |
RG-PA1200I-F |
1200 W AC module (AC/240 V HVDC) |
Fan Module
Product Model |
Description |
M1HFAN II-F |
Fan module (front-to-rear ventilation) |
100GE Optical Transceivers
Model |
Description |
100G-AOC-5M |
100G AOC, QSFP28 form factor, 5 m (16.40 ft.) |
100G-AOC-10M |
100G AOC, QSFP28 form factor, 10 m (32.81 ft.) |
100G-QSFP-SR-MM850 |
100G SR optical transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over multimode fiber (MMF) |
100G-QSFP-iLR4-SM1310 |
100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
100G-QSFP-LR4-SM1310 |
100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
100G-QSFP-ER4-SM1310 |
100GE ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF |
400GE Optical Transceivers
Model |
Description |
400G-QDD-SR8-MM850 |
400G optical transceiver, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF |
400G-QDD-DR4-SM1310 |
400G optical transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF |
400G-QDD-FR4-SM1310 |
400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
*400G-QDD-ZR-SM1550 |
400G ZR optical transceiver, QSFP-DD, Duplex LC, 1550 nm, 80 km (262,467.19 ft.) over SMF |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contáctenos
How can we help you?