Compare Products

Hide

Clear All

VS

RG-S6250-48XS8CQ Switch - 1
RG-S6250-48XS8CQ Switch - 2
RG-S6250-48XS8CQ Switch - 3
RG-S6250-48XS8CQ Switch - 4
RG-S6250-48XS8CQ Switch - 5
RG-S6250-48XS8CQ Switch - 6
RG-S6250-48XS8CQ Switch - 7
RG-S6250-48XS8CQ Switch - 8
RG-S6250-48XS8CQ Switch - 9
RG-S6250-48XS8CQ Switch - 10
RG-S6250-48XS8CQ Switch - 11
RG-S6250-48XS8CQ Switch - 1
RG-S6250-48XS8CQ Switch - 2
RG-S6250-48XS8CQ Switch - 3
RG-S6250-48XS8CQ Switch - 4
RG-S6250-48XS8CQ Switch - 5
RG-S6250-48XS8CQ Switch - 6
RG-S6250-48XS8CQ Switch - 7
RG-S6250-48XS8CQ Switch - 8
RG-S6250-48XS8CQ Switch - 9
RG-S6250-48XS8CQ Switch - 10
RG-S6250-48XS8CQ Switch - 11
Picture

RG-S6250-48XS8CQ 10GE Data Center Access Switch

M-LAG/VSU/de-stacking for higher availability, PFC/ECN-based lossless RDMA network with high performance

Models
Series
Highlight Features
  • 48 x 1G/10G SFP+ ports and 8 x 40G/100G QSFP28 ports
  • Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
  • VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient
Sales Enquiry
Key Specification View More
Fitur

Data Center 10GE Access Switch RG-S6250-48XS8CQ

10GE high-density access switch with 10GE/100GE downlink ports and 100GE uplink ports backward compatible with 40GE for adaptation to different scenarios
Large buffer and advanced buffer scheduling mechanism, providing fast data processing and easily coping with burst traffic

Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability

De-stacking

M-LAG

VSU

De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.

PFC- and ECN-based Lossless Ethernet with High Throughput and Low Latency in RDMA Scenarios

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden
and effectively solves the network latency problem.
PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M,
Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy.
The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

Spesifikasi

Hardware Specifications

Item

RG-S6250-48XS8CQ

Dimensions (W x D x H)

442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.)

Rack height

1 RU

Unit weight

5.6 kg (12.35 lbs., empty chassis)

8.2 kg (18.08 lbs., a chassis installed with two power modules and four fan modules)

Switching capacity

4.8 Tbps

Packet forwarding rate

2000 Mpps

Service port

48 x 1G/10G SFP+ ports

8 x 40G/100G QSFP28 ports

Management port

1 x RJ45 console port

1 x RJ45 MGMT port

USB port

1 x USB 2.0 port (Type A connector)

Module slot

2 x power module slots

4 x fan module slots

Power consumption

Maximum power consumption: 300 W

Typical power consumption: 165 W

Static power consumption: 98 W

Power input

RG-PA550I-F (AC input):

Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz

Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current: 7.2 A to 3.5 A (100 V AC to 240 V AC)

Power port type: C14

 

RG-PA550I-F (HVDC input):

Rated input voltage: 240 V DC

Maximum input voltage: 180 V DC to 310 V DC

Rated current: 3.6 A

Power port type: C14

 

RG-PHD550I-F (AC input):

Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz

Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current: 10 A

Power port type: C14

 

RG-PHD550I-F (HVDC input):

Rated input voltage: 336 V DC

Maximum input voltage: 160 V DC to 400 V DC

Rated input current: 10 A

Power port type: C14

 

RG-PD800I-F (DC input):

Rated input voltage: –48 V DC

Maximum input voltage: –36 V DC to –72 V DC

Rated input current: 23 A

Power port: three-pin power port

Temperature

Operating temperature: 0°C to 45°C (32°F to 113°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Humidity

Operating humidity: 10% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Altitude

Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Cooling

Air cooling, front-to-rear airflow (port-side intake)

 

Software Specifications

Item

RG-S6250-48XS8CQ

Layer 2 protocols

IEEE802.3ae (10GBase), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (static link aggregation, LACP, M-LAG), IEEE802.1p, IEEE802.1Q,

IEEE802.1D (STP), STP root guard, and BPDU guard

IEEE802.1w(RSTP), IEEE802.1s(MSTP)

IGMP Snooping v1/v2, MLD Snooping, Jumbo Frame(9Kbytes)

IEEE 802.1ad (QinQ and selective QinQ), GVRP, Three modes (access, trunk, and hybrid), LLDP, static MAC address, MAC address filtering, MAC address quantity limit

N/A

Layer 3 protocols (IPv4)

Static routing, BGP4, OSPFv2, IS-IS, RIPv1, RIPv2, MBGP, LPM routing, policy-based routing (PBR), route-policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, and Any-RP, BFD for BGP/IS-IS/OSPF/static routing, manual tunnel, GRE tunnel

Basic IPv6 protocols

Neighbor discovery, ICMPv6, path MTU discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, IS-ISv6, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS

IPv6 features

Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, IS-ISv6, IPv6 VRRP, MLDv1/v2, PIM-SMv6, manual tunnel, GRE tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel

Data center features

VXLAN routing and VXLAN bridging

EVPN VXLAN

VXLAN mapping

IPv4 VXLAN over IPv4

IPv6 VXLAN over IPv4

IPv6 VXLAN over IPv6

IPv6 VXLAN over IPv6

M-LAG

OpenFlow 1.3

RDMA, RoCEv2, PFC, and ECN

Process

gRPC

sFlow sampling

IPFIX sampling

QoS

IEEE 802.1p, ToS, and DSCP priority mapping

ACL traffic classifier, and priority tagging Mark/Remark

Various queue scheduling mechanisms such as SP (PQ), WRR, DRR, SP (PQ)+WRR, and SP (PQ)+DRR

Flexible queue scheduling algorithms based on ports or queues

Congestion avoidance mechanisms such as WRED and tail discarding

Ingress/egress port-based rate limiting and CAR

MPLS

MPLS VPN

Virtualization

Virtual switching unit (VSU)

Buffer management

Buffer usage monitoring and traffic microburst detection

High availability

GR for RIP/OSPF/BGP, BFD, DLDP, VRRP, VRRP load balancing/dual-active, BFD for VRRP, REUP, RLDP, 1+1 power redundancy and fan redundancy, and hot swappable line cards and power modules

Security features

Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), DDoS/DoS attack defense, ICMP attack defense, unauthorized packet detection, data encryption, source IP spoofing defense, IP scanning attack defense, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL, port-based ACL, or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, Telnet login from specified IP addresses, uRPF, broadcast packet suppression, DHCP snooping, ARP spoofing defense (ARP anti-spoofing), ARP check, and hierarchical user management

Management mode

SNMP v1/v2c/v3, Telnet, Console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, NETCONF, Python, fan and power alarm, temperature alarm, and configuration rollback

Other protocols

DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP Relay, Proxy ARP, and Syslog

Show More
Resources All Resources
Learn about Products or Solutions
Installation
Software and Configuration
Informasi Pemesanan

Chassis

Model

Description

RG-S6250-48XS8CQ

RG-S6250-48XS8CQ chassis, 48 x 10GE SFP+ ports, 8 x 100GE QSFP28 ports, 2 x power module slots, 4 x fan module slots. The chassis is equipped with two power modules (RG-PA550I-F) and four fan modules (M1EFAN II-F).

 

Power Modules

Model

Description

RG-PA550I-F

550 W power module (supporting AC and 240 V HVDC)

RG-PD800I-F

800 W power module (supporting 48 V LVDC) for the RG-S6250-48XS8CQ and the RG-S6510-48VS8CQ

RG-PA550I-R

550 W AC power module (rear-to-front airflow, supporting AC and 240 V HVDC), used with rear-to-front airflow fan module M1EFAN IV-R

RG-PHD550I-F

550 W AC power module (supporting 336 V HVDC)

 

Fan Modules

Model

Description

M1EFAN II-F

Fan module (port-side intake) for the RG-S6250-48XS8CQ

M1EFAN III-F

Fan module (port-side intake) for the RG-S6231-48XT8CQ, the RG-S6231-48XS8CQ, the RG-S6232-48XS8CQ, and the RG-S6501-48VS8CQ

M1EFAN IV-R

Fan module (fan-side intake), applicable to the RG-S6231-48XS8CQ and the RG-S6231-48XT8CQ

 

40G Optical Transceivers

Model

Description

40G-AOC-5M

40G QSFP+ active optical cable (AOC), 5 m (16.40 ft.)

40G-AOC-30M

40G QSFP+ active optical cable, 30 m (98.43 ft.)

40G-QSFP-SR-MM850

40G SR optical transceiver, QSFP+ form factor, MPO, 150 m (492.13 ft.) over multimode fiber (MMF)

40G-QSFP-LSR-MM850

40G SR optical transceiver, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF

40G-QSFP-LR4-SM1310

40G LR4 optical transceiver, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over single-mode fiber (SMF)

40G-QSFP-iLR4-SM1310

40G iLR4 optical transceiver, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF

40G-QSFP-LX4-SM1310

40G LX4 optical transceiver, QSFP+ form factor, Duplex LC, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF


100G Optical Transceivers

Model

Description

100G-AOC-5M

100G AOC, QSFP28 form factor, 5 m (16.40 ft.)

100G-AOC-10M

100G AOC, QSFP28 form factor, 10 m (32.81 ft.)

100G-QSFP-SR-MM850

100G SR optical transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF

100G-QSFP-iLR4-SM1310

100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

100G-QSFP-LR4-SM1310

100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

100G-QSFP-ER4-SM1310

100G ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF

 

GE Optical Transceivers

Model

Description

GE-SFP-LH40-SM1310-BIDI

1G LH optical transceiver, SFP form factor, BIDI LC, 40 km (131,233.60 ft.) over SMF

GE-SFP-LX20-SM1310-BIDI

1G LX optical transceiver, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF

GE-SFP-LX20-SM1550-BIDI

1G LX optical transceiver, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF

MINI-GBIC-LH40-SM1310

1G LH optical transceiver, SFP form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF

MINI-GBIC-LX-SM1310

1G LX optical transceiver, SFP form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF

MINI-GBIC-SX-MM850

1G SR optical transceiver, SFP form factor, Duplex LC, 550 m (1,804.46 ft.) over MMF

MINI-GBIC-ZX80-SM1550

1G ZX optical transceiver, SFP form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF

 

GE Copper Transceivers

Model

Description

Mini-GBIC-GT(F)

1G copper transceiver, SFP form factor, RJ45, used with Cat5e, Cat 6, and Cat6a, transmission distance of up to 100 m (328.08 ft.) For the RG-S6200 series products, the Mini-GBIC-GT(F) transceiver is applicable only to the RG-S6250-48XS8CQ.

Mini-GBIC-GT

1G copper transceiver, SFP form factor, RJ45, used with Cat5e, Cat 6, and Cat6a, transmission distance of up to 100 m (328.08 ft.)

 

10GE Optical Transceivers

Model

Description

XG-SFP-SR-MM850

10G SR optical transceiver, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF

XG-SFP-LR-SM1310

10G LR optical transceiver, SFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF

XG-SFP-ER-SM1550

10G ER optical transceiver, SFP+ form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF

XG-SFP-ZR-SM1550

10G ZR optical transceiver, SFP+ form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF

XG-LR-SM1310

10G LR optical transceiver, SFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF

XG-SFP-AOC1M

10G AOC, SFP+ form factor, 1 m (3.28 ft.)

XG-SFP-AOC3M

10G AOC, SFP+ form factor, 3 m (9.84 ft.)

XG-SFP-AOC5M

10G AOC, SFP+ form factor, 5 m (16.40 ft.)

XG-SR-MM850

10G SR optical transceiver, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF

Show More
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Contattaci

Contattaci

How can we help you?

Contattaci

Get an Order help

Contattaci

Get a tech support

Technical Support
Technical Support
Get in Touch
Get in Touch