| Hareware Specifications | S7805C | S7808C | S7810C | 
 
     
     | Interface Specifications | 
 
     
     | Power module | 2 | 2 | 4 | 
 
     
     | Supervisor module slot | 2 | 2 | 2 | 
 
     
     | Line card slot | 3 | 6 | 8 | 
 
     
     | Switch fabric module slot | Built-in | 2 (integrated with supervisor modules) | 4 (2 are integrated with supervisor modules) | 
 
     
     | System Specifications | 
 
     
     | Packet forwarding rate | 4,500 Mpps | 9,000 Mpps | 12,000 Mpps | 
 
     
     | System switching capacity | 6 Tbps | 12 Tbps | 16 Tbps | 
 
     
     | MAC address | ● Number of global MAC addresses EB card: 64,000 DA card: 96,000 (default) and 288,000 (max.) FA card: 80,000 FB card: 96,000 ● Number of static MAC addresses EB card: 4,000 DA card: 10,000 FA card: 4,000 ● FB card: 40,000 | 
 
     
     | ARP table | EB card: 10,000 (default and recommended) DA card: underlay: 75,000; overlay: 0 (default and recommended) FA card: underlay: 30,000; overlay: 0 FB card: underlay: 50,000; overlay: 0 (default and recommended) | 
 
     
     | Number of IPv4 unicast routes | EB card: 12,000 (default and recommended, shared with IPv6 routes)  DA card: 12,000 (default and recommended, shared with IPv6 routes) FA card: 12,000 (default and recommended, shared with IPv6 routes) FB card: 134,000 (default and recommended, shared with IPv6 routes) | 
 
     
     | Number of IPv4 multicast routes | EB card: 8,000 DA card: 16,000 FA card: 8,000 FB card: 16,000 | 
 
     
     | Number of IPv6 unicast routes | EB card: 6,000 (shared with IPv4 routes) DA card: 6,000 (shared with IPv4 routes) FA card: 6,000 (shared with IPv4 routes) FB card: 50,000 (shared with IPv4 routes) | 
 
     
     | Number of IPv6 multicast routes | EB card: 4,000 DA card: 8,000 FA card: 4,000 FB card: 8,000 | 
 
     
     | Number of ACEs | ● Ingress EB card: 3,500 DA card: 8,000 FA card: 5,000 FB card: 4,500 ● Egress EB card: 1,000 DA card: 1,000 FA card: 1,000 ● FB card: 2,000 | 
 
     
     | Number of VSU members | 2 | 2 | 2 | 
 
     
     | Dimensions and Weight | 
 
     
     | Dimensions (W x D x H) | 442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in., 4 RU) | 442 mm x 465mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in., 10 RU) | 442.5 mm x 560 mm x 442 mm (17.42 in. x 22.05 in. x 17.40 in., 10 RU) | 
 
     
     | Weight (empty chassis and fan modules) | 32.35 kg (71.32 lbs) | 35.6 kg (78.48 lbs) | 43.6 kg (96.12 lbs) | 
 
     
     | CPU and Storage | 
 
     
     | CPU | ● Supervisor module M7805C-CM II: 1.5 GHz quad-core processor ● Service module EA/EB card: 1.0 GHz quad-core processor DA/F card: 1.5 GHz quad-core processor | ● Supervisor module M7808C-CM II: 1.5 GHz quad-core processor ● Service module EA/EB card: 1.0 GHz quad-core processor DA/F card: 1.5 GHz quad-core processor | ● Supervisor module M7808C-CM II: 1.5 GHz quad-core processor ● Service module EB card: 1.0 GHz quad-core processor DA/F card: 1.5 GHz quad-core processor ● Switch fabric module M7810C-FE-D I/M7810C-FE-F I: 1.5 GHz quad-core processor | 
 
     
     | Storage | Flash memory M7805C-CM II: 1 GB EA card: 512 MB EB card: 512 MB DA/F card: 8 GB SDRAM M7805C-CM II: DDRIII 4 GB EA card: DDR3 1 GB EB card: DDRIII 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB | Flash memory Supervisor module: M7808C-CM II: 8 GB Service module: EA card: 512 MB EB card: 512 MB DA/F card: 8 GB SDRAM Supervisor module: M7808C-CM II: DDR4 4 GB Service module: EB card: DDR3 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB | Flash memory Supervisor module: M7810C-CM/M7810C-CM-F: 8 GB Service module: EB card: 512 MB DA/F card: 8 GB Switch fabric module: M7810C-FE-D I: 8 GB M7810C-FE-F I: 8 GB SDRAM Supervisor module: M7810C-CM/M7810C-CM-F: DDR4 4 GB Service module: EB card: DDR3 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB Switch fabric module: M7810C-FE-D I card: DDR4 1 GB M7810C-FE-F I: DDR4 2 GB | 
 
     
     | Power and Consumption | 
 
     
     | Maximum power consumption | Chassis RG-S7805C: < 80 W Supervisor module: M7805C-CM II: < 21 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-8CQ-FB: < 130 W | Chassis RG-S7808C: < 176 W Supervisor module: M7808C-CM II: < 50 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-8CQ-FB: < 130 W | Chassis RG-S7810C: < 432 W Supervisor module: M7810C-CM: < 50 W M7810C-CM-F: < 110 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-8CQ-FB: < 130 W Switch fabric module: M7810C-FE-D I: < 50 W M7810C-FE-F I: < 105 W | 
 
     
     | Maximum output power | ● RG-PA300I-F: 90 V to 180 V; Power: 300 W 180 V to 264 V; Power: 300 W   ● RG-PA460I-F: 90 V to 180 V; Power: 460 W 180 V to 264 V; Power: 460 W | ● RG-PA600I-F: 600 W ● RG-PA1600I-F: 90 V to 180 V: 12,00 W 180 V to 264 V: 1,600 W   | ● RG-PA600I: 600 W ● RG-PA1600I: 90 V to 180 V: 1,200 W 180 V to 264 V: 1,600 W | 
 
     
     | Environment and Reliability | 
 
     
     | MTBF | > 200,000 hours | 
 
     
     | Primary Airflow | ● Supervisor module Right-to-left airflow ● Service module Right-to-rear airflow ● System power module Built-in fan modules drawing air outward Front-to-rear airflow | ● Supervisor module /Service module Right-to-rear airflow ● System power module Front-to-rear airflow | ● Line card Side-to-rear airflow ● Supervisor module/FE Front-to-rear airflow | 
 
     
     | Operating temperature | 0°C to 50°C (32°F to 122°F) | 
 
     
     | Storage temperature | –40°C to +70°C (–40°F to +158°F) | 
 
     
     | Operating humidity | 10% to 90% RH (non-condensing) | 
 
     
     | Storage humidity | 5% to 95% RH (non-condensing) | 
 
     
     | Operating altitude | –500 m to +5,000 m (–1640.42 ft. to +16404.20 ft.) | 
 
     
     | Operating noise | 55.9 dB at the temperature of 35°C (95°F) 73.4 dB at the temperature of 50°C (122°F) | 
 
     
     | Interface surge protection | All electrical ports support 4 kV surge protection in common mode or 1 kV surge protection in differential mode. | Power port: 6 kV Telecom port: 4 kV (MGMT port) |